Installation of ViewCheck

ViewCheck on ATCA-9405 Installation and Use (6806800S51C)

36

Please enter password:

Exporting licenses.....

License files transfer completed. For details check

/var/log/exportLicense.log log file.

Installing the ViewCheck Service OS image on PP

The following procedure is to boot the ViewCheck OOS image on PP. For more information,
refer to section 2.6.5 in Blade Services Software on ATCA-9405 Programmer’s Reference Guide.

1. On SP, go to /opt/diagnostics/etc/diag/ location and execute the

runlinux scripts.

For installing ViewCheck Service OS image on PP1, execute ./runlinux 1
command.

For installing ViewCheck Service OS image on PP2, execute ./runlinux 2
command.

Installing ViewCheck Service OS Image on USB

The ViewCheck service OS image can be installed on any external USB drive using flashprep
and flashinstall tools available on the board.

The TFTP server IP mentioned while exporting the license should be same from where
OOSD image will be loaded.

Before installing ViewCheck Service OS image on PP, make sure that vlans are configured
appropriately to reach Octeons.