Installation of ViewCheck

ViewCheck on ATCA-9405 Installation and Use (6806800S51C)

41

show-test-result Show test result

show-test-status Show test status

show-upper-threshold-info Show upper threshold info.

start-monitor Start a monitor

start-test Start a test

stop-monitor Stop a monitor

stop-test Stop a test

After logging into the CLI, user can start, stop and query a test from the CLI.

Below is an example of FloodPingTest in the network interface device category. In network
interface category mode test ID 1. For more information, refer to

NETWORK

on page 90

.

You can view the details of the test by giving show-test-help command.

BSF(diag-SP_VEE0-networkinterface)#show-test-help testId 1

1.FloodPingTest

Runs flood ping. Syntax: "FloodPingTest eth0-1 aa.bb.cc.dd"

TestCapbaility:Cancellable

Service OS:Not Required(Non-Service Impacting)

A list of device Instances supported under a device category can be viewed by giving list-
device-instances

. To start the test, user can run start-test command with testId,

deviceInstance

and arguments as input to the command. The arguments can be

neglected for tests that does not take any arguments as input.

After the test is executed, the results can be viewed by show-test-result command,
which outputs the test result and the raw log generated by that test.

BSF(diag-SP_VEE0-networkinterface)#list-device-instances

nwcontlr(131), eth0(62),eth1(63),eth2(64)

BSF(diag-SP_VEE0-networkinterface)#show-test-result testId 1

deviceInstance 63

Test Result: PASSED

Test Started Invocation Id: 7

Test Start Time: Mon Nov 26 09:31:22 2012

Test Stop Time: Mon Nov 26 09:31:23 2012

Test Log File:

/opt/diagnostics/var/log/diag/testlog/NETWORK_eth1.log