18 start-diag-scan, Table 5-9, Start-diag-scan – Artesyn ViewCheck on ATCA-9405 Installation and Use (May 2014) User Manual
Page 67: Commands execution
Commands Execution
ViewCheck on ATCA-9405 Installation and Use (6806800S51C)
67
</Object>
<Method>startAllMonitors</Method>
<Argument>
<Name>device-category</Name>
<Value>{Dev category String}</Value>
</Argument>
</InvokeMethod>
</Script>]]>]]>
5.2.18 start-diag-scan
start-diag-scan
starts the diag-scan on the mention device categories.
Syntax for CLI
start-diag-scan deviceCategory <Dev category-1>,…,<Dev category-N>
Iterations <Itr-num> haltOnError <halt-string>
The following table provides the start-diag-scan command arguments.
Syntax for XML
<Script>
<InvokeMethod>
<Object>
<Class>diagnostic</Class>
<Name>SP_VEE0</Name>
Table 5-9 start-diag-scan
Argument
Data Type
Description
Dev category1-N
String
Separate device categories using comma ’,’.
Itr-num
String
Iterations specifies the number of times a test case can
be executed. haltOnError specifies whether to
continue or stop with test case execution on the
occurrence of any error. Both options are optional and
their default values are "1" and "YES" respectively.
Maximum number of iterations that user can specify is
1000.
halt-string
String
Optional parameter. Yes or No.