16 stove installation – Avalon Firestyles Olympic User Manual

Page 16

Advertising
background image

16 Stove

Installation

(for qualified installers only)

© Travis Industries

93508061

4150520

Hearth Stove Direct
Connection

NOTE:

Direct connections require
installation of an airtight,
non-combustible block-off
plate or damper adapter.

Figure 14

Interior or Exterior
Masonry Chimney

NOTE:

This type of installation
requires a UBC approved
masonry connector or a
factory built (U.L. Listed)
wall thimble.

Figure 15

Block-off plate or
damper adapter

Remove damper
or wire it open

Airtight
Insulated
Clean-Out

Stainless steel
chimney connector
must Extend 1' past
the block-off plate or
to the flue liner

NOTE: The chimney must have a clay
tile liner. If it does not, the installation
must use a positive connection (full
reline). The entire fireplace and
chimney must be clean, undamaged,
and meet all local building codes (UBC,
etc.). Damage must be repaired prior
to installation. The chimney must be
15' to 33' tall.

Clay
Liner

Floor Protection
(See the section "Floor
Protection Requirements"
for more details)

Combustible Mantle

Min. 18"

See the section
"Stove Placement
Requirements" for
minimum clearances
required.

Max. 8”

Make sure the
clean-out seals in
place.

Clay Liner

See the section "Stove
Placement Requirements" for
minimum clearances required.

Min. 18"
clearance
to ceiling

This type of
installation requires
a UBC approved
masonry connector
or a factory built
(U.L. Listed) wall
thimble.

Chimney connector sections

NOTE: The chimney must have a
clay tile liner. If it does not, the
installation must use a positive
connection (full reline). The
entire fireplace and chimney must
be clean, undamaged, and meet
all local building codes (UBC,
etc.). Damage must be repaired
prior to installation. The chimney
must be 15' to 33' tall.

See the section
"Floor Protection
Requirements"