20 fireplace insert installation, Minimum clearances, Insert placement requirements – Avalon Firestyles Olympic User Manual

Page 20: Hearth requirements, Masonry fireplace requirements

Advertising
background image

20 Fireplace

Insert

Installation

(for qualified installers only)

© Travis Industries

93508061

4150520

Insert Placement Requirements

 The insert must be placed so that no combustibles are within, or can swing within (e.g. drapes,

doors), 36" of the front of the insert

 Insert and hearth must be installed on a level, secure floor
 The minimum clearances, facing, and hearth requirements in Figure 18 must be met.

Figure 18

Hearth Requirements

 Must extend 16" in front of the insert and 8" on both sides (min. 19" deep by 39-5/8" wide)
 Must be non-combustible and at least .018" thick (26 gauge)

Masonry Fireplace Requirements

 Chimney must have a clay tile liner or a stainless steel liner (positive connection)
 Entire fireplace, including chimney, must be clean and undamaged. Any damage must be repaired

prior to installation of the insert

 Chimney height: 15' minimum; 33' maximum.
 Entire fireplace, including chimney, must meet local building requirements

Side
Wall

Combustible Mantel

Combustible Top Facing

Non-Combustible

Hearth

Facing

Standard

Model

Cook-Top

Model

Minimum Clearances

k

l

m

n

o

p

q

x

Sidewall to Insert

Side Facing

Top Facing

with Mantel Shield

Mantel to Insert

with Mantel Shield

Hearth (Front)*

Hearth (Side)

Front of Insert

Extension onto Hearth

15"

13-1/2"

30"

17"

32"

19"

16"

8"

36"

6-3/8"

15"

13-1/2"

31"

18"

33"

20"

16"

8"

36"

8-7/8"

* Does not include the distance the insert

extends onto the hearth (dimension "x").

q

x

l

k

m

n

o

p

Advertising