Listing information 41, Do not remove this label, Olympic – Avalon Firestyles Olympic User Manual

Page 41: Freestanding installation

Advertising
background image

Listing

Information

41

© Travis Industries

93508061

4150520

Listing Label

DO NOT REMOVE THIS LABEL

CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT INSTALLATION AND RESTRICTIONS IN YOUR AREA.

SUITABLE FOR USE IN CONVENTIONAL RESIDENTIAL INSTALLATIONS, MANUFACTURED HOMES AND ALCOVES.

MODEL:

OLYMPIC

Certified for USA and Canada

SERIAL NO:

Report No. B0499PRT-001

Control No. 4000515

CONFORMS TO: UL STD 1482; CERTIFIED TO ULC STD S627-2000, ULC STD S628-1993

PREVENT HOUSE FIRES - Install and use only in accordance with the manufacturer’s installation and operating instructions. Contact your local building or fire officials
about restrictions and installation inspection in your area. Refer to local building codes and manufacturer’s instructions for precautions required for passing a
chimney through a combustible wall or ceiling. Do not run a chimney connector through a combustible wall or ceiling. Do not connect this unit to a chimney flue
serving another appliance. Clearances may be reduced by methods specified in NFPA 211, listed wall shields, pipe shields, or other means approved by local building
or fire officials.

FREESTANDING INSTALLATION

STANDARD RESIDENTIAL FREESTANDING INSTALLATIONS REQUIRE: 6” diameter, minimum 24 MSG black, with listed UL-103 HT factory-built chimney, suitable for
use with solid fuels or masonry chimney. Pedestal or legs are required.

ALCOVE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. Pedestal or legs are required.

MANUFACTURED HOME AND REDUCED CLEARANCE INSTALLATIONS REQUIRE: One of the Listed doublewall connectors listed below. In addition, manufactured
home installations require outside air - use the optional pedestal or outside air boot.

● AMERI-TEC model DCC connector with model HS chimney

● DURA-VENT model DVL connector with DURA-PLUS chimney

● GSW-JAKES EVANS SUPERPIPE 2100

● I.C.C. EXCEL (103-HT) chimney with HP connector

● METALFAB model DW connector with TG chimney

● OLIVER MACLEOD PROVENT model PV connector with model 3103 chimney

● SECURITY model DP connector with SECURITY model ASHT or S2100 chimney

● SELKIRK METALBESTOS model DS connector with model SSII chimney

● OLYMPIA VENTIS

®

with Ventis doublewall black stove pipe

A.

B.

C.

D.

E.

F.

G.

H.

16 in. / 407 mm

15 in. / 381 mm

9.5 in. / 242 mm

27.5 in. / 699 mm

17.5 in. / 445 mm

20.5 in. / 521 mm

US: 6 in.

(153 mm) / CAN: 8 in. (204 mm)

US: 16 in.

(407 mm) / CAN: 18 in. (458 mm)

16 in. / 407 mm

10 in. / 254 mm

7.5 in. / 191 mm

27 in. / 686 mm

12 in. / 305 mm

18 in. / 458 mm

US: 6 in.

(153 mm) / CAN: 8 in. (204 mm)

US: 16 in.

(407 mm) / CAN: 18 in. (458 mm)

Singlewall Connector

Conventional Residential

Installations

Minimum Clearances

To Combustibles And

Hearth Requirements:

Alcove, Manufactured Home and Reduced

Clearance Conventional Residential

Installations

FREESTANDING CLEARANCE DIAGRAM

ALCOVE SPECIFICATIONS

FLOOR PROTECTION DIAGRAM

STOVE

D

A

E

B

ST

OVE

45˚

F

C

SIDEW

A

LL

BACKWALL

ADJACENT WALL

ADJACENT W

A

LL

G

STOVE

G

G

H

FRONT

FLOOR PROTECTOR

Floor protection must be a non-combustible
material extending beneath the heater and to
the front, sides and back as indicated. See
Owner’s Manual for examples of non-com-
bustible materials that can be used.
Do not obstruct space beneath heater.

Max. Alcove Depth:

Min. Alcove Height:

Min. Alcove Width:

48 in.

See Owner’s Manual

See Owner’s Manual

FACTORY-BUILT (Z.C.) FIREPLACE OR MASONRY FIREPLACE INSTALLATION

INSERT

A

F

B

D

C

E

HEARTH EXTENSION

MANTEL

COMBUSTUBLE SIDEW

A

LL

COMBUSTIBLE F

ACING

NON-COMBUSTIBLE
FIREPLACE FACING

Minimum Clearance to

Combustibles and Hearth

Requirements

Standard

Model

Cook Top

Model

A.
B.
C.

With Shield

D.

With Shield

E. (US)

E.(Can)

F. (US)

F. (Can)

15 in. / 381 mm

13.5 in. / 343 mm

30 in. / 762 mm
17 in. / 432 mm
32 in. / 813 mm
19 in. / 483 mm
16 in. / 407 mm
18 in. / 458 mm

6 in. / 153 mm
8 in. / 204 mm

15 in. / 381 mm

13.5 in. / 343 mm

31 in. / 788 mm
18 in. / 458 mm
33 in. / 839 mm
20 in. / 508 mm
16 in. / 407 mm
18 in. / 458 mm

6.0 in. / 153 mm
8.0 in. / 204 mm

Factory-Built (Z.C.) Fireplace installations require a minimum 24” starter section directly connected to the fireplace chimney or a full re-line. Factory-Built (Z.C.)
Fireplace chimney must have a minimum cross-sectional area of 28.85 square inches. The Factory-Built (Z.C.) Fireplace damper and control must be removed, or
secured in the open position. For minimum Factory-Built (Z.C.) Fireplace firebox size, see manufacturer’s installation instructions. Factory-Built (Z.C.) Fireplace floor
protection must be 3/8” minimum non-combustible material or equivalent, extending 16” in front of insert and 8” to both sides. A metal deflector plate must be installed
if the flue collar is not completely behind the Lintel plate of the Factory-Built (Z.C.) Fireplace openings.

Electrical Rating:
Optional Blower:

115V., 60 Hz., 1.8 Amps
SKU # 99000138, 99000190

Replace glass only with 5mm neoceramic or
ceramic glass.

Do not route power cord under or in front of appliance.

TRAVIS INDUSTRIES, INC.

12521 Harbour Reach Drive

Mukilteo, WA 98275

Manufactured by:

www.travisproducts.com

Made in U.S.A.

2015

2016

2017

2018

Jan

Feb

Mar

Apr

May

Jun

Jul

Aug

Sep

Oct

Nov

Dec

DATE OF MANUFACTURE

U.S. ENVIRONMENTAL PROTECTION AGENCY

Certified to comply with 2015 particulate emission standards. Not approved for sale after May 15, 2020. 2.6 g/h, Method 28, 5H, 2015

0914