22 fireplace insert installation – Avalon Firestyles Olympic User Manual

Page 22

Advertising
background image

22 Fireplace

Insert

Installation

(for qualified installers only)

© Travis Industries

93508061

4150520

Insert with
Positive
Connection

Figure 20

Insert with Direct
Connection
(Masonry
Fireplace)

NOTE:

Direct connections
require installation of
an airtight block-off
plate or damper
adapter (see "Block-off
Plate Installation" on
page 21).

The liner must be
stainless steel
connector or flexible
vent. Follow the liner
manufacturer's
insturctions for
installation and
support.

Remove damper
or wire it open

Airtight Insulated
Clean-Out

Combustible Mantle

Flue Liner

See the section "Insert
Placement Requirements" for
minimum clearances and
hearth required.

Cap (prevents water
from entering)

Install a non-combustible
cover plate to prevent water
from entering the chimney

Surround Panels

Block-off plate or
damper adapter

Remove
damper
or wire it
open

Airtight
Insulated
Clean-Out

Stainless steel
chimney connector
must Extend 1' past
the block-off plate or
to the flue liner

Combustible Mantle

Flue
Liner

See the section
"Insert Placement
Requirements" for
minimum clearances
and hearth required.

Surround Panels

Advertising