Facing detail, Nstallation, For qualified installers only – Avalon Firestyles DVS Fireplace-1997 to 2000 User Manual

Page 11

Advertising
background image

I

NSTALLATION

(C

ONT

.)

- For Qualified Installers Only!

P

AGE

11

Facing Detail

Access Door

1-1/2"

Face

1"

1-7/16Ó Lopi Discovery
1-7/16Ó Avanti DVS
7/16Ó FPX Rect. and Arched

Glass

1/8"

Air Space

The overlap is 1-1/2" along
the top of the face.

NOTE:

Do not tuck tile underneath the face on the bottom (there
will be a 1/8" air space below the access door). You may
do this on the sides and top, but not on the bottom.

29-1/8Ó

20-3/8Ó

1"

1-1/2"

Make sure these shaded areas are faced over
when using the arched face. Rectangular faces
do not require this area to be faced.

4-7/8Ó

+

To achieve a facing that is flush with the drywall to the side of the fireplace, recess the framing
directly next to the fireplace. See the illustration below.

Fireplace

1"

1/2" Drywall

1/2" Concrete Board

3/8" Tile

This 2x4 is recessed 3/8"
to make a flush facing

Fireplace

1/2" Drywall

1/2" Concrete Board

3/8" Tile

The tile overlaps the drywall
for an overlap facing

Faceplate

1"

TOP
VIEW

Faceplate