Fireplace placement requirements, Setting up the standoffs, Minimum framing dimensions – Avalon Firestyles DVS Fireplace-1997 to 2000 User Manual

Page 7: Clearances, Nstallation

Advertising
background image

I

NSTALLATION

(C

ONT

.)

- For Qualified Installers Only!

P

AGE

7

Fireplace Placement Requirements

Setting Up the Standoffs

Standoff

a

Replace the screw to
secure the standoff.

Bend the standofff in
the sequence shown.

1/4" Nutdriver

Remove the screw
below the standoff.

b

1

2

3

c

The standoffs are shipped in the flat position. Make sure to follow the instructions
below before installing the fireplace.

AFTER

BEFORE

!

WARNING

: Failure to set up the standoffs will result in an extreme fire hazard

.

Minimum Framing Dimensions

¥

The 1/2" stand-offs on
the back and sides and 6-
1/4" stand-offs on the
top of the fireplace are
designed to separate the
fireplace from the
framing members.
These stand-offs may
contact the framing
members but no material
may be placed between
the stand-offs.

¥

Fireplace must be
installed on a level
surface capable of
supporting the fireplace
and vent

¥

Fireplace must be placed
directly on wood or non-
combustible surface (not
on linoleum or carpet)

¥

Due to the high
temperature of the
fireplace, it should be
located out of traffic and
away from furniture and
draperies.

Gas Line (the inlet is 7-3/4" behind the
framing and 2-5/8" above the base of the
fireplace (see "Gas Line Connection" for
details).

37-1/4"

19-5/8"

35"

Route the electrical line (and optional
thermostat or remote control wire) to
the right of the fireplace.

NOTE: when venting to the rear, allow a
min. 8-5/8" gap centered behind the
fireplace (for the vent and wall thimble).

36" From Base of Fireplace.

NOTE: when using an elbow off the top of the
fireplace, allow for a 2" clearance above the
vent (1" to the sides and bottom).

Clearances

¥

When installed, walls in front of the fireplace must be a minimum 6" to the side of the faceplate.

¥

Fireplace must be placed so that no combustibles are within, or can swing within 36" of the front of
the fireplace (e.g. drapes, doors)

¥

Fireplace must be placed so the vents below and above the glass do not become blocked