Remote Thermostat

!

Do not connect 110-120 VAC to the gas control valve or wiring system of this unit.

¥

Follow the instructions included with the remote thermostat for installation.

IMPORTANT OPERATIONAL NOTE FOR REMOTE THERMOSTAT USE:

Included with the remote thermostat is a set of instructions that should be given to the homeowner.
Please be aware that the remote thermostat has a 1 to 2 minute lag time between the time the
thermostat is turned up and the heater turns on.

Decorative

Fireback (part # 98500732)

The decorative classic fireback attaches to the side walls of the firebox to enhance the aesthetic quality
of the appliance. The directions below detail installation.

!

Turn the gas control valve to "OFF" prior to conducting any service.

1

The faceplate, glass, and log set must be removed prior to installing the firebacks.

2

Use a 5/16" socket wrench or standard screwdriver to remove the four screws on each side of
the firebox wall (see the illustration below).

3

Attach the fireback clips to the side walls using 1/2" screws included with this kit.

4

Place the firebacks onto the fireback clips. The side plates are marked "Left" and "Right" on
the back to differentiate the two sides. Insert the 1" screws included with this kit through the
plates and into the walls of the firebox to secure the plates in place. Do not fully tighten the
screws - the firebacks should have some space to expand and contract.

The fireback rests on
the fireback clip.