Installation – Avalon Firestyles Hideaway User Manual

Page 10

Advertising
background image

1 0

Installation

(for qualified installers only)

Travis Industries

4030612

1 0 0 - 0 1 1 4 8

Corner Installations

A typical 45° installation
uses the minimum framing
dimensions shown in the
illustration to the right
(NOTE: all clearances still
apply).

The recommended
dimensions shown to the
right allow additional
space, easing gas line
and electrical
connections.

1/2" Standoffs

5-1/2" Min.
6-1/2" Recommended

Min. 1/2"

Clearance

NOTE: do not insert any material into

the 1/2" gap along the front of the

fireplace.

22-1/4" Min.
24-7/8" Recommended

Raised Fireplaces

The fireplace (and
hearth, if desired) may
be placed on a platform
designed to support the
fireplace (125 Lbs.) and
vent.

The fireplace may not be
raised so as to place the
ceiling in front of the
fireplace within 57" of
the base of the fireplace.

Raised
Platform

Optional Hearth

Minimum

57"

Ceiling

Fireplace Enclosure

(min. 48")