Installation, Horizontal terminations – Avalon Firestyles Hideaway User Manual

Page 18

Advertising
background image

1 8

Installation

(for qualified installers only)

Travis Industries

4030612

1 0 0 - 0 1 1 4 8

Horizontal Terminations

5.

Use a single 90°
elbow (NOTE:
an additional 45°
elbow may be
used on the
horizontal run).

6.

If using 6-5/8"
diameter vent, a
minimum 12"
vertical section is
required.

7.

The termination
must fall within
the shaded area
shown in the
chart. Use the
indicated
restrictor
position.

5 feet

10 feet

0 feet

0 feet

5 feet

5 feet

0 feet

0 feet

10 feet

5 feet

10 feet

14'

(max)

10 feet

Restrictor

Position # 1

14 feet

(max)

14 feet

(max)

14 feet
(max)

NOTE:

If using 6-5/8" diameter vent, a minimum 12" vertical section is required.

NOTE:

Horizontal sections require a 1/4" rise every 12" of travel.

NOTE:

Restrictor positions are based upon lab tests. The ideal restrictor position