Installation, Vent configurations with vertical vent termination, For qualified installers only) – Avalon Firestyles Hideaway User Manual

Page 17: Travis industries

Advertising
background image

Installation

(for qualified installers only)

1 7

Travis Industries

4030612

1 0 0 - 0 1 1 4 8

Vent Configurations with Vertical Vent Termination

The termination must fall within the shaded area shown in the chart. Use the indicated restrictor position.

A maximum of 3 elbows may be used.

8" or 6-5/8" diameter vent may be used.

5 feet

10 feet

15 feet

20 feet

25 feet

30 feet

0 feet

40' (max)

5 feet

10 feet

0 feet

5 feet

10 feet

14' (max)

15 feet

20 feet

25 feet

30 feet

0 feet

0 feet

NOTE:

Horizontal sections require a

1/4" rise every 12" of travel.

10 feet

40' (max)

14' (max)

NOTE:
Restrictor positions are
based upon lab tests.
The ideal restrictor
position may vary
slightly, especially when
the termination is near a
demarkation line.

5 feet

NOTE:

One 45° or 90° elbow may

be used between horizontal

sections. Horizontal length

is caculated by adding each

horizontal run together.

35 feet

35 feet

Restrictor

Position # 1

Restrictor

Position # 4

Restrictor

Position # 6

6' (min)

6' (min)

NOTE:

Two 45° elbows

may be used.