Installation

(for qualified installers only)

2 5

Travis Industries

4030612

1 0 0 - 0 1 1 4 8

Facing Detail –Facing Over 1” Thick (Brick)

WARNING: Any facing that extends in front of the faceplate on the sides or top must be non-

combustible.

NOTE:

A 3/8” gap is required above the face for face installation.

Top View

NOTE: Make sure to leave a 1/8" gap

around the sides of the face and 3/8"

above (for face installation).

Fireplace

Face

Drywall

Framing

Non-combustible facing material (brick, stone,

marble, tile) - required if the facing extends in front

of the face on the sides or top.

1/4"

The facing is brought up

to the wall trim.

The side facing should be spaced 1/8"

from the face (3/8" from the flange on

the side stand-offs)

Wall Trim

Side View

Fireplace

NOTE: Make sure to bring the facing up

to the wall trim.

In this example brick is used.

1/8"

3-d View