Installation, Ab c, For qualified installers only) – Avalon Firestyles Hideaway User Manual

Page 13: Travis industries, Optional electrical line location

Advertising
background image

Installation

(for qualified installers only)

1 3

Travis Industries

4030612

1 0 0 - 0 1 1 4 8

Electrical Line Connection

a

b

Insert the sheathed cable from the power source through

this cable clamp. Once the wires are attached, tighten

the clamp to secure the cable.

Replace the

cover removed

in step "a".

Attach the common (white), ground (exposed or green)

wires, and hot (black) wires from the power source to the

electrical connector (attached to the fireplace).

c

d

Standard
Screwdriver

Remove the cover

from the fireplace

junction box.

1/4" Nutdriver

WARNING: Make sure power is

off from the power lead before

conducting any wiring.

Electrical

Connector

Optional Electrical Line Location

Remove the two screws securing the

electrical inlet (save these screws).

Remove the cover plate on the bottom of the

fireplace (save these nuts).

Position the electrical inlet assembly over the

hole in the baseplate of the fireplace and

secure using the screws removed in step “b”.

a

b

c

Position the cover plate over the

electrical inlet hole on the right side

of the fireplace and secure using the

nuts removed in step “a”.

d

7/16" Wrench