Installation, Vent requirements – Avalon Firestyles Hideaway User Manual

Page 14

Advertising
background image

1 4

Installation

(for qualified installers only)

Travis Industries

4030612

1 0 0 - 0 1 1 4 8

Vent Requirements

The gas appliance and vent system must be vented directly to the outside of the building, and never
be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas
appliance must use it's own separate vent system.

Vent Clearances

The vent must maintain the required clearance to combustible materials to prevent a fire (see
“Clearances” below). Do not fill air spaces with insulation.

Min. 2" Clearance Above

45° Sloping Vent

0" Clearance to the sides

after the first firestop.

Use a firestop whenever

passing through a

ceiling, enclosure or

floor penetration.

Use a firestop when passing

through any wall (WARNING:

some firestops provide a 1"

clearance above the vent -- 2"

is required for this heater).

Min. 2" Clearance

Above the Vent

1/2" Clearance to the

front of vent before the

first firestop.

0" Clearance Below the Vent

after the first firestop.

0" Clearance to the

side of vent after the

first firestop.

Altitude Considerations

This heater has been tested at altitudes ranging from sea level to 8,000 feet (2,400 M). In this testing we have
found that the heater, with its standard orifice, burns correctly with just an air shutter adjustment.

Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard.
Consult your dealer or installer if you suspect an improperly adjusted air shutter.

Approved Vent

Use Model GS Direct Vent manufactured by Simpson Dura-Vent

only

. Follow the installation

instructions included with the vent. For the nearest Simpson Dura-Vent supplier, call (800) 835-4429.

This fireplace accepts 8" diameter GS Direct Vent. Vent configurations with at least 12" of rise may
use 6-5/8" diameter GS Direct Vent (use the adapter - part # 98900165).
See "Approved Vent Configurations" for further details on vent.

Always use the high-wind cap for the type of vent you are using.

Advertising