Installation, Facing requirements – Avalon Firestyles Hideaway User Manual

Page 21

Advertising
background image

Installation

(for qualified installers only)

2 1

Travis Industries

4030612

1 0 0 - 0 1 1 4 8

Facing Requirements

NOTE: The combustible area above the facing must not protrude more than 3/4" from the facing. If it

does, it is considered a mantel and must meet the mantel requirements listed in this manual.

Facing Under 1” Thick

The facing (combustible
or non-combustible)
must maintain a 1/2”
clearance to the sides
and top of the fireplace.

Any material that protrudes
more than 3/4” in front of the
facing is considered a mantel
and must meet the mantel
requirements in this manual.

4-3/4”

30-1/4”
(approx.)

3-3/8”

NOTE: The facing tucks
behind the flanges.

NOTE The facing tucks under the notch at the front
of the fireplace (3/8” above the base of the fireplace).

a

b

c

Recommended Order of Installation We
recommend installing the facing (drywall, tile)
under the notch at the front of the fireplace
(“a”) - then install the sides and top (“b” and
“c”)

Facing Over 1” Thick

Facing that protrudes in front of the face above the face (or within 1/2” of each side) must be made of
non-combustible materials.

N O T E

A 3/8" gap above the face is required for face installation and removal.

Advertising