Installation, Vent requirements – Avalon Firestyles Salish EF-2000 to 2001 User Manual

Page 10

Advertising
background image

8

Installation

(for qualified installers only)

Travis Industries

9 3 5 0 8 1 2 2

1 4 1 1 0 0

Vent Requirements

!

Always maintain the required 1” clearance (air space) to combustible materials to prevent a fire hazard.
Do not fill air spaces with insulation.

!

The gas appliance and vent system must be vented directly to the outside of the building, and never
be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas
appliance must use it’s own separate vent system.

This appliance is equipped only for
altitudes 0-2000 feet. However, our
in-house testing has shown that the
unit operated at altitudes to 8000 ft.

!

Failure to adjust the air shutter
properly may lead to improper
combustion which can create a safety
hazard. Consult your dealer or
installer if you suspect an improperly
adjusted air shutter.

When the vent passes through a wall,
a wall thimble is required. When the
vent passes through a ceiling, a
support box or firestop is required.
When the vent passes through the
roof, a roof flashing and storm collar
are required. Follow the instructions
provided with the vent (from
Duravent®) for installing these items.

Use a firestop spacer whenever
passing through a ceiling
(Duravent Part #963)

Vertical Termination
(Duravent Part # 991)

Use a roof flashing and storm collar
whenever passing through the roof
(Duravent Part #953 & #943 or #943S)

8-5/8"

Use a support box
on exposed vent

Vertical Vent

Requirements

Use a wall thimble
whenever passing
through a wall
(Duravent Part #942)

Horizontal Termination
(Duravent Part #984)

Maintain a minimum 1" clearance
from vent to any combustible
(vent is 6 5/8" diameter)

Minimum
Framing for
wall thimble

Horizontal Vent

Requirements

Minimum framing
for fire stop

8-5/8"

Maintain a minimum 1"
clearance from vent to
any combustible (vent
is 6 5/8" diameter)

Use Model GS Direct Vent manufactured by Simpson Dura-Vent

only

(or the Chimney Conversion Kit

- see Addendum #2). Follow the installation instructions included with the vent. For the nearest
Simpson Dura-Vent supplier, call (800) 835-4429. Part numbers and descriptions are listed below.

Straight Lengths

908B

6” Pipe Length, Black (interior)

907B

9” Pipe Length, Black (interior)

906

12” Pipe Length, Galvanized

906B

12” Pipe Length, Black (interior)

904

24” Pipe Length, Galvanized

904B

24” Pipe Length, Black (interior)

903

36” Pipe Length, Galvanized

903B

36” Pipe Length, Black (interior)

902

48” Pipe Length, Galvanized

902B

48” Pipe Length, Black (interior)

911B

11” to 14 5/8” Pipe, Adjustable, Black (interior)

Vent Terminations

981

Snorkel Termination (36” rise)

(for basement installations)
982

Snorkel Termination (14” rise)

(for basement installations)
984

Horizontal Square Termination

950

Vinyl Siding Standoff

991

Vertical Termination

Elbows

990

90• Elbow

990B

90• Elbow, Black (interior)

945

45° Elbow

945B

45° Elbow, Black (interior)

Penetration, Support Parts

942

Wall Thimble

940

Optional Wall Thimble Cover

941

Cathedral Ceiling Support Box

943

Flashing, 0/12 to 6/12 Roof Pitch

943S

Flashing, 7/12 to 12/12 Roof

Pitch
953

Storm Collar

963

Ceiling Firestop

988

Wall Strap

Apply a 1/8" bead of high-temperature silicone or Mill-Pac® to the inner
and outer pipe before assembling the sections (on the male, upper
section). This seals the inner pipe from the outer pipe. Slide the sections
together and turn 1/4 turn until the sections lock in place. Install three
metal screws through each joint to lock the outer section in place (see the
instructions included with the vent for further details).

NOTE: You may screw the first section of vent to the appliance.

Horizontal sections require a 1/4” rise every 12” of travel

+

Exterior Vent Diameter = 6-5/8” , Inner Vent Diameter = 4”

Horizontal sections require non-combustible support every 36” (e.g.: use
plumbing tape)

Advertising