Installation, For qualified installers only) – Avalon Firestyles Salish EF-2000 to 2001 User Manual

Page 13

Advertising
background image

Installation

(for qualified installers only)

11

Travis Industries

9 3 5 0 8 1 2 2

1 4 1 1 0 0

Approved Venting Configurations with a Horizontal Termination

If using a Snorkel Termination (14” or 36”) add the snorkel height to the vertical height (snorkel
terminations are used primarily for basement installations).

The termination must fall within the shaded area shown in the chart. Use restrictor position #1.

Natural Gas (NG)
Installations

Propane (LP)
Installations

5 feet

0 feet

10' (max)

0 feet

5 feet

0 feet

0 feet

NOTE:

Horizontal sections

require a 1/4" rise every

12" of travel.

12 feet

(max)

NOTE:

A minimum 2 foot rise is required

directly off of the stove.

12 feet (max)

5 feet

10' (max)

5 feet

Use Restrictor Position # 1

(all shaded areas)

5 feet

0 feet

11' (max)

0 feet

5 feet

0 feet

0 feet

NOTE:

Horizontal sections

require a 1/4" rise every

12" of travel.

NOTE:

A minimum 3 foot rise is required

directly off of the stove.

12 feet (max)

11' (max)

5 feet

Use Restrictor Position # 1

(all shaded areas)

12 feet

(max)

5 feet

Advertising