Optional equipment, Wall thermostat – Avalon Firestyles Salish EF-2000 to 2001 User Manual

Page 36

Advertising
background image

34

Optional Equipment

Travis Industries

9 3 5 0 8 1 2 2

1 4 1 1 0 0

Wall Thermostat

(Part # 99300650)

WARNING:

Turn the gas control valve to off and make sure the appliance has fully cooled prior to
conducting service.

N O T E :

Do not connect 120 VAC to the gas control valve or wiring of this unit.

1

Cut the quick-connects off of the thermostat wire. Expose approximately 1/4” of wire from the wires
and attach to the upper and lower terminals on the gas control valve (see the illustration below).

Attach the thermostat wires to

the top and bottom posts on the

gas control valve.

Standard

Screwdriver

Thermostat

Wire

2

Route the wire to the rear of the stove. Determine a location for the thermostat that is within range of
the 50' length of thermostat wire. It should be centralized in the room and away from the heater. The
wire may be routed externally on the wall or behind the wall (preferred).

3

Cut the thermostat wire so there is approximately 6" of slack (NOTE: Do not splice thermostat wires
together–this leads to too much electrical resistance). Follow the directions below to install the
thermostat.

50 60 70 80 90

50 60 70 80 90

Robertshaw

Run the thermostat wires

through the wall (cut off excess

wire, leaving 6” of slack).

Pull the cover off the thermostat

Expose 1/2” of wire and

attach to these two posts.

Standard

Screwdriver

Attach the thermostat to

the wall through these

two holes.

a

b

c

d

Re-attach the cover

removed in step “a”.

e

4

Set the on/off switch on the stove to “Off”. If turned to “On” the stove will remain on always.

Advertising