Optional Equipment

33

Travis Industries

9 3 5 0 8 1 2 2

1 4 1 1 0 0

8

Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-
test all gas connections and the gas control valve. Check the pilot. Adjust if necessary.

WARNING:

When lighting or re-lighting the pilot, the door must be opened (see
page 17).

Standard
Screwdriver

The pilot flame must contact the thermocouple and

thermopile (see the illustration below). Adjust the pilot up or

down as necessary.

To adjust the pilot flame, turn this screw (NOTE: if totally

unscrewed gas will come out of this port). Clockwise

lowers the flame while counter-clockwise raises it.

Fireback (part # 98500754)

Follow the directions below to install the optional firebrick. Remove the log set prior to installation.

b

5/16" Nutdriver

Remove the two screws on

the back wall of the firebox.

Use these screws to secure

two fireback clips.

a

Remove the two screws on

the sides of the firebox and

the single screw on the

back wall.

Place the rear fireback on the clips

installed in step “a”. Secure the

fireback with the screw removed in

step “b”.

c

Place the side firebacks along

the sides of the firebox. Secure

with the fireback clips and the

screws removed in step “b”.

d