Cable interface – Avery Dennison 9400 Series Programmer Manual User Manual

Page 15

Advertising
background image

Cable Interface

The printer accepts standard RS-232C electrical signal
transmissions when it is connected to a DB-25S connector
configured as Data Terminal Equipment (DTE). For correct
operation, use all defined pins.

PC null modems

Plug the RS-232 cable into:

A serial (RS-232) port on your host computer or
protocol converter

The 25-pin RS-232 connector on your printer. See
"Installing the Printer" in your

Equipment Manual.

The RS-232C cable interface is set up as a terminal device
(DTE):

Pin

Description

3

Received Data

5

Clear to Send

Input

6

Data Set Ready

2

Transmitted data

4

Request to send

Output

20

Data Terminal Ready

1

Protective ground

Ground

7

Signal ground

All other pins are open.