Read message from rs232 serial port – Aviosys 9216 User Manual

Page 11

Advertising
background image

IP SENSOR 9216 USER MANUAL

The last number of the IP address (default is 100) can be any number between 1~254, but cannot be the same
with that of the computer’s. If you want to use it at home, you can enter the web page by typing in the IP, the IE,
or using ipedit.exe program.

*Same subnet : means the first three parts of the IP address must be the same, such as XXX.XXX.X.abc. For
example, 192.168.1.100 and 192.168.1.123 are in the same subnet.

4. The default username and password of IP Sensor 9216 are:

Username: admin
Password: 12345678


If forget password and can not log in webpage, please press Reset for 10 second , after few second

then restart power . Then the IP address and password will be back to default value


Read message from RS232 serial port

User can read the system state of 9216 in PC through the RS232 serial port in 9216.
First, connect the 9216 serial port to PC serial port and make sure the connection is correct.
Then, click the start menu in your PC, program---accessories---communicate---super terminal, setting as
the figure below shows:

* Bits per second ;19200
* Data bits : 8
* Parity :None
* Stop bits: 1
* Flow control : NONE
























Then you can read message of 9216 from RS232 serial port.





- 10 -