RS232 interface   

 

 

 

9.17.027 

 

3.6

S

TATUS MESSAGE

 

A write to a device with the command “01” will result in a status message. Below the possible returns are listed. 
 

Nr 

Byte 

Description 

Start character 

04 

Fixed message length 4.

Node 

Node address 

00 

Command status 

Status 

00 No error 
01 Process claimed 
02 Command error 
03 Process error 
04 Parameter error 
05 Parameter type error 
06 Parameter value error 
07 Network not active 
08 Time‐out start character 
09 Time‐out serial line 
0A Hardware memory error 
0B Node number error 
0C General communication error 
0D Read only parameter. 
0E Error PC‐communication 
0F No RS232 connection 
10 PC out of memory 
11 Write only parameter 
12 System configuration unknown 
13 No free node address 
14 Wrong interface type 
15 Error serial port connection 
16 Error opening communication 
17 Communication error 
18 Error interface bus master 
19 Timeout answer 
1A No start character 
1B Error first digit 
1C Buffer overflow in host 
1D Buffer overflow 
1E No answer found 
1F Error closing communication 
20 Synchronisation error 
21 Send error 
22 Protocol error 
23 Buffer overflow in module 

Index or Claimed 

process 

Index pointing to the first byte in the send message for which the above status applies. 
In case of the status CLAIM ERROR, this field contains the claimed process. 

\r 

Carriage Return 

\n 

Line Feed 

 

 

Value from byte 5 of status message may be neglected if value of byte 4 = 0 

 