MINIMUM BURNER SETTING ADJUSTMENT

In the minimum position the flame must have a length of about 4 mm and must
remain lit even when turned quickly from the maximum position to minimum.

The flame adjustment is done in the following way:

- Turn on the burner

- Tum the tap to the MINIMUM position

- Take off the knob

- With a small flat screwdriver turn the screw inside the tap rod to the correct regula-

tion (fig. 3.5).

Normally for G30/G31, the regulation screw is tightened up.

Fig. 3.5