Connecting load cells to j-box, Changing setup and calibration numbers, Setup – Digi-Star EZ 3600V Manual USB User Manual

Page 41

Advertising
background image

Installation

D3715-GB Rev E EZ3600 User's manual

38

Connecting load cells to J-Box

Figure4: J-Box connections



Changing setup and calibration numbers

[

SETUP] & [CAL]

1. Enter 871.

2. Press .

3. Weighing indicator briefly shows

SETUP

followed by a six digit number. Enter the
new number.

4. Press

.


Use 872 and follow the same procedure to
change the calibration

CAL number.

Tighten nuts

Load cell cable

J-Box cable

Connect to bottom panel of weighing
indicator. See figure 3.

1/3

2

SETUP

4

3

Connection of wires from

load cell cable to terminals.

Wire colours

Pin Colour

Description

1 Red

Excitation +

2 Green

Signal -

3 White

Signal +

4 Black

Excitation -

4 Transparent

Shield

J-Box with 4 load cell
connections

Advertising