Weigh methods – Digi-Star StockWeigh 500 User Manual

Page 14

Advertising
background image

StockWeigh 500

D3632 US-B

10

Weigh Methods

General - Weigh Method #1

The General weigh method is an all-purpose weigh method for weighing dead loads. It is

commonly used for weighing dead.

Slow - Weigh Method #2

The Slow weigh method attempts to provide higher accuracy by filtering many weight

samples over a longer period of time. Small, instantaneous weight changes have less effect

on the displayed weight using this technique. This method is for weighing dead loads.

Fast - Weigh Method #3

The Fast weigh method is more sensitive to weight changes than the other weigh methods.

When a weight changes quickly, the Fast method tries to determine the new weight as

quickly as possible. This method is for weighing dead loads.

Lock-on - Weigh Method #4

Set to “LOCKON” for animal weighing, this allows scale to weigh active animals and display

an accurate weight that does not fluctuate. Set to “OFF” for weighing dead weights. Lock-On

sensitivity can be adjusted using the “LOCKON” menu.
Once the actual weight is displayed, the scale “Locks-On” to the displayed. Weight does not

change, even if the motion never stops. A small ‘L’ appears on the left side of the display

indicating the weight is “Locked-On.” The animal’s weight must be greater than 2.5% of the

scales “capacity” weight before the system can “Lock-On.”
In order to break the lock, 50% of the displayed weight must be either added or removed

from the scale. The “Locked-On” weight can be “rechecked” by pressing the [ZERO] key on

the front panel. This breaks the “lock” and the scale recalculates the weight.

Note:

Setting the Weigh Method in the “Long Form” DOES NOT affect the Display Unit LB-

KG.

Note:

In Weigh Method #1, #2 and #3 the ZTRACK (zero-tracking) removes up to 0.05% of

the scale capacity (as shown in setup). In Weigh Method #4 the weight that can be removed

is set to 5lbs(2.2kg).