Using long form setup – Digi-Star StockWeigh 500 User Manual

Page 9

Advertising
background image

Operators Manual

D3632 US-B

5

Using Long Form Setup

Use Long form Setup to change the optional settings described on pages 3 and 4.

Turning Zero Tracking “OFF”

1. Enter Long Form by holding [Net-Gross] and pushing the [ON/Record] key for three

seconds.

2. Press the [ON/Record] key to advance to “ZTRACK” menu.
3. Press the [Net/Gross] key to select “OFF”. See page 3 for more Zero Tracking

information.

4. Press the [ON/Record] key to advance to the next menu item.

Selecting Weigh Method

1. Enter Long Form by holding [Net-Gross] and pushing the [ON/Record] key for three

seconds.

2. Press the [ON/Record] key to advance to “W MTHD” menu.
3. Press the [Net/Gross] key several times until “4” is displayed for animal weighing.

See page 3 and “Appendix B” for more Weigh Method information.

4. Press the [ON/Record] key to advance to the next menu item.

Adjusting Lock-On Performance

1.

Enter Long Form by holding [Net-Gross] and pushing the [ON/Record] key for

three seconds.

2.

Press the [ON/Record] key to advance to “LOCKON” menu.

3.

Press [Net/Gross] to select the desired value (1 thru 9) for the “Lock On” setting.

See page 3 for more Lock-On information.

4.

Press the [ON/Record] key to advance to the next menu item.

Turning Lock-N-Hold "OFF”

1. Enter Long Form by holding [Net-Gross] and pushing the [ON/Record] key for three

seconds.

2. Press the [ON/Record] key to advance to “LKNHLD” menu.
3. Press the [Net/Gross] key to select “OFF”. See page 4 for more Lock-N-Hold

information.

4. Press the [ON/Record] key to advance to the next menu item.