Optional settings – Digi-Star StockWeigh 500 User Manual

Page 7

Advertising
background image

Operators Manual

D3632 US-B

3

Low Battery Indication

If the supply voltage drops below the (10.5 Volts), the message “

” and “

” will periodically show on the display to alert the

operator of the low battery condition. After 2 minutes the indicator will shut off.

WARNING:

Disconnect the indicator from the battery while recharging. Damage can

occur to the indicator.

Self Test

Press [NET/GROSS] then [ON/Record] during normal system operation to start the self-test.

Optional Settings

The Indicator has optional settings that allow flexibility in the way that the scale is used and

data is collected. To change optional settings enter “Long Form Setup” by pushing

[Net/Gross] and then [On/Record] for three seconds.

Default settings for the indicator are as follows:

!

These parameters can be selected, de-selected or adjusted to fit the way you use the scale.

See below for descriptions.

ZTRACK

(Zero Tracking) If “ON”, the scale will adjust for small weight

variances of up to 5lbs in the Lock-On weigh method. This allows

the scale to compensate for such things as mud or snow

accumulation on the scale platform.

W MTHD

(Weigh Method) Weigh method allows the operator to adjust how

much number-crunching the scale processor does to the load cell

data before displaying the weight. See Appendix “C” for details.

Select weigh method #4 “Lock-On” for animal weighing.

LOCKON

(Lock-On)

Available settings are 1 thru 9. A low value, such as a

1 or 2, allows the system to be more sensitive to animal motion. A

high value, such as an 8 or 9, allows the scale to lock on faster.

Use the lowest setting that still allows the system to lock on

consistently.