StockWeigh 500

D3632 US-B

2

IMPORTANT!

If the rear end of a working chute is not bolted solidly to a concrete foundation, then it must

be restrained from movement greater than about one inch with a chain or other flexible

means.

Technical Manual:

Technical manual is available upon request. Please call (920) 563-9700 and request Digi-

Star Technical Manual (F3583).
If connecting to load cells that were not provided with your system, the indicator must be

calibrated to weigh properly. Contact Digi-Star Technical Support for assistance. Phone

(920) 563-9700.

Turning ON the Scale

Press [ON/Record].
A brief “hello” message will be displayed. The scale enters the GROSS weighing mode.
GROSS mode displays the weight change since the unit was last ZERO/BALANCED.

Zero Balance the Scale

Press the [NET/GROSS] key and within three seconds, press the [ZERO/RECHECK] key.
The ZERO/BALANCE will “balance off” the dead load such as the platform weight or any

attachment to the platform.
“ZERO” is displayed to show completion of the step and the scale is put in the GROSS

mode.

Standard Operation (Using Default Settings)

To view and adjust the default setting, see “Optional Settings” and “Using Long Form Setup”

starting on page 6.

Weighing Animals

1.

Connect load cells and power. Turn “ON” indicator.

2.

“Zero Balance” the scale by pressing [NET/GROSS] then press

[ZERO/RECHECK] within 3 seconds.

3.

Bring the animal onto the scale platform.

4.

After a few seconds the indicator “Locks On” to an animal’s weight, and an “L”

will show in the upper left corner of the display.

5.

Release the animal. When the animal steps off the scale, it is ready for the next

animal.

To Recheck Lock-On Weight

While the animal is still on the scale platform, press the [ZERO/RECHECK] key to

“RECHECK” or recalculate the weight of the animal.