D3632 US-B

11

Net and Gross Mode

To Select Gross Mode

GROSS mode displays the weight change since the unit was last ZERO/BALANCED.

Press [NET/GROSS]

Note:

The scale is in GROSS mode if there is a flashing arrow pointing toward the GROSS

text just above the [ON/RECORD] key.
Gross mode is used for single animal weighing.

To Select Net Mode:

NET mode displays the weight change after a TARE has been performed. TARE is a

temporary “zero” point.
If the scale “TARE” weight has not been entered, press [TARE] to acquire a “zero.”
Or
If in Gross mode, press [NET/GROSS]. The [NET/GROSS] key is an alternating action key.

If the scale is in the GROSS mode, pressing the [NET/GROSS] key will place it in the NET

mode. If the scale is in the NET mode, pressing the [NET/GROSS] key will place it in the

GROSS mode.
The scale is in NET mode if there is a flashing arrow pointing toward the NET text in the

lower left corner of the display.