Weighing errors – Digi-Star StockWeigh 500 User Manual
Page 19
Operators Manual
D3632 US-B
15
Weighing Errors
OVRCAP
Capacity Limit:
The display shows the message
"
"
if the weight on the scale system exceeds the
capacity limit. The capacity value is entered in SETUP to warn of overloading the scale
system.
+RANGE
Over Range:
The display shows the message
"
"
if the weight on the scale system exceeds the
maximum weight measurable by the scale system. The over range value is always the
system’s maximum A/D counts multiplied by the scaling factor. The actual weight at which
over range occurs depends on the calibration, zero, and display count size.
-RANGE
Under Range:
The display shows the message
"-
"
if the weight on the scale system is less than the
minimum weight measurable by the scale system. The under range value is always the
system’s minimum A/D counts multiplied by the scaling factor. The actual weight at which
under-range occurs will depend on the calibration number, zero, and display count size.