3 lifting, 4 storage – Flowserve MENBLOC 60Hz User Manual

Page 12

Advertising
background image

MENBLOC 60Hz USER INSTRUCTIONS ENGLISH 71559945 - 02/13

Page 12 of 36

flowserve.com

2 Poles

North America

Metric

Unit

mass

Motor

mass

MENBLOC (Hp)

MENBLOC (kW)

kg

lb

kg

lb

2 x 1¼ - 5-2

50-32-125/1.2-2

28

62

13

29

2 x 1¼ x 6-3

50-32-160/2.2-2

46

101

21

46

2 x 1¼ x 6-5

50-32-160/3-2

49

108

24

53

2 x 1¼ x 8-5

50-32-200/4.6-2

57

126

29

64

2 x 1¼ x 8-10

50-32-200/6.5-2

79

174

41

90

2 x 1¼ x 8L-10

50-32-200L/8.5-2

82

181

49

108

2 x 1¼ x 8L-20

50-32-200L/13-2

100 220

67

148

2½ x 1½ x 5-3

65-40-125/2.2-2

44

97

21

46

2½ x 1½ x 5-5

65-40-125/3-2

47

104

24

53

2½ x 1½ x 6-5

65-40-160/4.6-2

55

121

29

64

2½ x 1½ x 8L-10

65-40-200L/8.5-2

83

183

49

108

2½ x 1½ x 8L-20

65-40-200L/13-2

101 223

67

148

2½ x 1½ x 10-20

65-40-250/13-2

108 238

67

148

2½ x 1½ x 10-20

65-40-250/16-2

119 262

78

172

2½ x 1½ x 10L-25 65-40-250L/18.5-2* 200 441 137 302

2½ x 1½ x 10L-30

65-40-250L/22-2*

220 485 150 331

2½ x 1½ x 10L-40

65-40-250L/30-2*

298 657 233 514

2½ x 2 x 5-5

65-50-125/3-2

49

108

24

53

2½ x 2 x 5-5

65-50-125/4.6-2

54

119

29

64

2½ x 2 x 6-5

65-50-160/4.6-2

63

139

29

64

2½ x 2 x 6-10

65-50-160/6.5-2

75

165

41

90

2½ x 2 x 8L-25

65-50-200L/18.5-2* 189 417 137 302

2½ x 2 x 8L-30

65-50-200L/22-2*

220 485 150 331

2½ x 2 x 10L-40

65-50-250L/30-2*

297 655 233 514

3 x 2½ x 5-5

80-65-125/3-2

53

117

24

53

3 x 2½ x 5-5

80-65-125/4.6-2

58

128

29

64

3 x 2½ x 5-10

80-65-125/6.5-2

70

154

41

90

3 x 2½ x 6-20

80-65-160/13-2

103 227

67

148

3 x 2½ x 6-20

80-65-160/16-2

114 251

78

172

3 x 2½ x 8L-30

80-65-200L/22-2*

221 487 150 331

3 x 2½ x 8L-40

80-65-200L/30-2*

295 650 233 514

3 x 2½ x 8L-50

80-65-200L/37-2*

312 688 249 549

4 x 3 x 6-20

100-80-160/13-2

106 234

67

148

4 x 3 x 6-20

100-80-160/16-2

117 258

78

172

4 x 3 x 8L-30

100-80-200L/22-2* 244 538 150 331

4 x 3 x 8L-40

100-80-200L/30-2* 311 686 233 514

4 x 3 x 8L-50

100-80-200L/37-2* 328 723 249 549

* IP 55 motor (added pump shaft)

Pieces below 25 kg (55 lb) can be manually

handled but operators should wear protection gloves
and exercise caution.

2.3 Lifting

2.3.1 Slinging of motor pumps units

Use handling means in accordance with motor

pump unit mass mentioned on the CE plate. For the
masses of the pumps bare end of shaft see table §
2.2.2 and nameplate.

To avoid distortion, the pump unit

should be lifted as shown.

A crane must be used for all pump sets in

excess of 25kg (55 Ib). Fully trained personnel must
carry out lifting, in accordance with local regulations.

Motor pump unit

When handling always wear gloves, safety

boots and an industrial safety helmet.

For masses above 25 kg (55 lb), manual

handling is forbidden.

2.4 Storage

Store the pump in a clean, dry

location away from vibration. Leave piping
connection covers in place to keep dirt and other
foreign material out of pump casing. Turn pump at
intervals to prevent brinelling of the bearings and the
seal faces, if fitted, from sticking.

Do not store pumps starting on the fan guard.

The pump may be stored as above for up to 6
months. Consult Flowserve for preservative actions
when a longer storage period is needed.

The pump must be stored in a non explosive,

ventilated location, sheltered from bad weather, dust
and vibrations.

Advertising