6 assembly – Flowserve MENBLOC 60Hz User Manual

Page 31

Advertising
background image

MENBLOC 60Hz USER INSTRUCTIONS ENGLISH 71559945 - 02/13

Page 31 of 36

flowserve.com

6.6 Assembly

6.6.1 Reassembly of the MENBLOC unit

REASSEMBLY OPERATIONS

MENBLOC

WITH AN

ADDED

PUMP SHAFT

MENBLOC

WITH AN

EXTENDED

MOTOR

SHAFT

Fit the [2110] pump shaft on
the motor shaft end with its
[6700-01] key

X

Screw and tighten the [6570]
screw in the hole of the motor
shaft end

X

Put the motor vertically shaft
end upwards. Take
precautions not to damage the
fan cover

X

X

Put the [9331] shield grid into
the cover for motor casing

X

Mount the lantern bracket
[3180] on the motor. Screw
and tighten the [6577-03] bolts
and the [6581] hexagon nuts

X

Mount the [1221] casing cover
with stuffing box on the [3130]
cover of motor casing and
respect the orientation (the 2
casing cover ribs facing the 2
oblong holes of the cover for
motor casing)

X

Mount the [1221] casing cover
on the [3180] lantern bracket
and respect the orientation

X

For an unclamped casing
cover: screw and tighten the
[6577-02] bolts with an
appropriate wrench tightening
opposing bolts and working
around the casing

X

X

Put the fixed ring of the [4200]
mechanical seal into soapy
water and mount it in the
casing cover

X

X

Plunge rotating ring into soapy
water

X

X

Mount the complete stationary
ring, the spring and the seat of
the [4200] mechanical seal

X

X

Mount the [6700] or [6700-02]
key

X

X

Mount the [2250] impeller on
the shaft end and avoid
damaging the mechanical seal
seat

X

X

Mount the [2905] plain washer.
Screw and tighten the [6570]
screw with an appropriate key
(fix the rotor in position)

X

X


REASSEMBLY OPERATIONS

MENBLOC

WITH AN

ADDED

PUMP

SHAFT

MENBLOC

WITH

EXTENDED

MOTOR

SHAFT

Mount the [4590-03] special ring
on the casing cover. Mount the
pump shaft and respect the
orientation

X

X

Screw the [6577-01] or [02] bolts.
Tighten opposing bolts working
around the cover with an
appropriate wrench (do not use a
striking-face wrench)

For MENBLOC

80-65-125, 80-65-160, 80-65-200L,
100-80-160, 100-125-250L, the
[6577-01] bolts have to be
mounted with sealing product
LOCTITE pipe sealant 577 or
similar.

X

X

Check the correct rotation of the
rotor with an appropriate key at the
shaft end

X

X

Reinstall the unit according to the
rules defined in this manual

X

X

TO REINSTALL DIRECLY THE ELECTRIC MOTOR

The [6570] screw stays in the shaft
threading but does not hinder the
assembly, install the motor, mount
and block the [6577-03] bolts and
the [6581] nuts

X

Push on the pump shaft end
without shocks or blows until the
pump shaft presses against the
shoulders of the motor shaft.
Tighten the [6570] screw. (see the
following fig. 1)

X

To avoid loosening of the screw
during the running of the pump use
a nut locking compound, after
having pain carefully degreased
the screw and the threading

X

These recommendations correspond to a

complete assembly and to a complete dismantling.
For a partial dismantling, only certain areas will be
relevant.

The torques to be applied are:

Casing / casing Cover /Lantern [6577]

Screw [6570]

m.daN

lbf.ft

Nm

lbf.ft

M10

3

22

"

16

12

M12

5

37

½"

41

30

M16

11

81

M12

60

44

M14

80

59

M18

120

89

M20

140

103

M24

160

118