Figure 4-9: Casing material correction factors

Material Group No.

1.0

1.1

2.1

2.2

2.4

2.8

3.2

3.4

3.5

3.7

3.8

3.17

Ti

Cr

Austenitic steels

Nickel and nickel alloys

Tem

p ˚C

Tem

p ˚F

DCI

Carbon

Steel

Type

304
and

304L

Type

316
and

316L

Type

321

CD-

4MCu

Nickel

Monel

Inconel

Hast

B

Hast

C

Alloy

20

Ti,
Ti-

Pd,

Zr

High

Chrome

-18 to

171 ˚C

(0 to

340 ˚F)

-129

-200

-

-

1.00

1.00

1.00

-

0.50

-

-

-

-

0.83

-

-

-73

-100

-

-

1.00

1.00

1.00

1.00

0.50

0.83

0.93

1.00

1.00

0.83

0.89

-

-29

-20

0.89

1.00

1.00

1.00

1.00

1.00

0.50

0.83

0.93

1.00

1.00

0.83

0.89

0.65

38

100

0.89

1.00

1.00

1.00

1.00

1.00

0.50

0.83

0.93

1.00

1.00

0.83

0.89

0.65

93

200

0.83

0.94

0.83

0.86

0.93

1.00

0.50

0.74

0.88

1.00

1.00

0.72

0.86

0.65

150

300

0.78

0.91

0.75

0.78

0.83

0.92

0.50

0.69

0.82

1.01

1.01

0.65

0.81

0.65

205

400

0.73

0.88

0.69

0.72

0.69

0.85

0.50

0.67

0.77

0.98

0.98

0.58

0.69

0.65

260

500

0.69

0.83

0.63

0.67

0.64

0.80

0.50

0.66

0.74

0.92

0.92

0.54

0.57

-

315

600

0.65

0.76

0.60

0.63

0.60

0.77

0.50

0.66

0.74

0.84

0.84

0.50

0.45

-

Note: see specific temperature limitations of Guardian pumps in Sections 3-6 and 3-7.



Figure 4-10: Baseplate correction factors

Base type

Grouted

Bolted

Stilt

mounted

Type A

1.0

0.7

0.65

Type B - Polybase

1.0

NA

0.95

Type C

N/A

1.0

1.0

Type D

1.0

0.8

0.75

Type E - PIP

1.0

0.95

N/A

Polyshield - baseplate
/foundation

1.0

N/A

N/A

Advertising