GAI-Tronics LE200-RM Rack-Mount Page/Party Line Extender User Manual

Page 27

Advertising
background image

Pub. 42004-392G

M

ODEL

LE200-RM

R

ACK

-M

OUNT

P

AGE

/P

ARTY

®

L

INE

E

XTENDER

P

AGE

25 of 56

e:\standard ioms - current release\42004 instr. manuals\42004-392g.doc
09/14

Series Connection of Page/Party

®

System

Figure 9. Series Connection of Page/Party

®

System

Table 26. Series Connection of Page/Party

®

System Table

Parameter Switch

Configuration

Description

T1 Line Length SW2

Determined by installation distance between each pair of Line Extenders:
 A to B
 C to D

T1/E1 Clock
Source

SW3-1

SW3-2

 Units A and C are the master T1/E1 clock sources:
SW3-1 (open) SW3-2 (open)
 Unit B is the slave and uses the T1/E1 clock from Unit A:
SW3-1 (closed) SW3-2 (closed)
 Unit D is the slave and uses the T1/E1 clock from Unit C:
SW3-1 (closed) SW3-2 (closed)

LVDS Clock
Source

SW3-3

SW3-4

LVDS clock is used between units B and C:

 Unit B - “in” disabled, “out” enabled:
SW3-3 (open) SW3-4 (closed)
 Unit C - “in” enabled, “out” disabled:
SW3-3 (closed) SW3-4 (open)

Mute Analog
Lines

SW6-4

Unit C is muted since there is not a Page/Party

®

cable connected:

SW6-4

(closed)