GAI-Tronics LE200-RM Rack-Mount Page/Party Line Extender User Manual

Page 6

Advertising
background image

Pub. 42004-392G

M

ODEL

LE200-RM

R

ACK

-M

OUNT

P

AGE

/P

ARTY

®

L

INE

E

XTENDER

P

AGE

4 of 56

e:\standard ioms - current release\42004 instr. manuals\42004-392g.doc
09/14

Audio Termination Connection Module – Optional Model 12118-011 Kit

The GAI-Tronics Model 12118-011 Kit must be used if the LE200-RM is to be connected directly to a
Page/Party

®

system. This kit consists of a ribbon cable for connection to the LE200-RM, an Audio

Termination Connection Module for connection to the Page/Party

®

system and mounting hardware. The

page line and party line 1–5 conductors of the Page/Party

®

system cable connect to the Audio Termination

Connection Module. This module also can provide the 33-ohm line balance resistance needed for the
audio lines. Audio line functions are described later in this manual.

Figure 4. Audio Termination Connection Module

Advertising