Testing and Troubleshooting

Generating Audio Test Signals

The Model LE200-RM is capable of generating several testing waveforms onto the audio lines of the
page/party system to aid in system testing and troubleshooting. Rotary switch SW1 on the Main PCBA
determines which Page/Party

®

audio line will receive the test waveform. DIP switch SW2 determines

which testing waveform is generated. Closing DIP switch SW2-8 enables the test waveform. Switches
SW2-5 through SW2-7 select a test waveform. Note that the frequency selections are different on the
selected audio party line. Refer to tables below for valid switch settings.

Table 49.


SW1

Selected

Page/Party

®

Line

Selected Tone

SW2-5 SW2-6 SW2-7 SW2-8

1

Party line #1

7 kHz (sine wave)

Open

Open

Open

Closed

6

Page line

4 kHz (sine wave)

Closed

Open

Open

Closed

2 kHz (sine wave)

Open

Closed

Open

Closed

1 kHz (sine wave)

Closed

Closed

Open

Closed

500 Hz (sine wave)

Open

Open

Closed

Closed

125 Hz (sine wave)

Closed

Open

Closed

Closed

1 kHz (saw tooth wave)

Open Closed Closed Closed

31 Hz pulses

Closed Closed Closed Closed


SW1

Selected

Page/Party

®

Line

Selected Tone

SW2-5 SW2-6 SW2-7 SW2-8

2

Party line #2

3.5 kHz (sine wave)

Open

Open

Open

Closed

3

Party line #3

2.0 kHz (sine wave)

Closed

Open

Open

Closed

4

Party line #4

1.0 kHz (sine wave)

Open

Closed

Open

Closed

5

Party line #5

500 Hz (sine wave) Closed

Closed

Open

Closed

250 Hz (sine wave)

Open

Open

Closed

Closed

125 Hz (sine wave)

Closed

Open

Closed

Closed

1 kHz (saw tooth wave)

Open Closed Closed Closed

31 Hz Pulses

Closed Closed Closed Closed

N

OTE

: Remember to restore SW1 to “0” and SW2 to its initial setting when no longer generating test

signals.

Advertising