T1/e1 data connections – GAI-Tronics LE200-RM Rack-Mount Page/Party Line Extender User Manual

Page 31

Advertising
background image

Pub. 42004-392G

M

ODEL

LE200-RM

R

ACK

-M

OUNT

P

AGE

/P

ARTY

®

L

INE

E

XTENDER

P

AGE

29 of 56

e:\standard ioms - current release\42004 instr. manuals\42004-392g.doc
09/14

When using GAI-Tronics 60029 Series system cable, follow the wiring color code as shown in Table 27
below:

Table 27. Color Codes for GAI-Tronics 60029 Series System Cable


Terminal


Designator

GTC System

Cable Color Code


Description

P5-1/P8-1 PAGE

-

L1

Red/blue

Page line audio

P5-2/P8-2 PAGE

-

L2

Blue/red

P5-3/P8-3

PARTY 1 - L1

Red

Party line 1 audio

P5-4/P8-4

PARTY 1 - L2

Tan/red

P5-5/P8-5

PARTY 2 - L1

Violet

Party line 2 audio

P5-6/P8-6

PARTY 2 - L2

Tan/violet

P5-7/P8-7

PARTY 3 - L1

Blue

Party line 3 audio

P5-8/P8-8

PARTY 3 - L2

Tan/blue

P5-9/P8-9

PARTY 4 - L1

Brown

Party line 4 audio

P5-10/P8-10

PARTY 4 - L2

Tan/brown

P5-11/P8-11

PARTY 5 - L1

Yellow

Party line 5 audio

P5-12/P8-12

PARTY 5 - L2

Tan/yellow

T1/E1 Data Connections

A two-pair cable is required for the T1/E1 data line connection between Line Extenders. Connect the
T1/E1 data cable to P19 on the Main PCBA. The transmit (TX) and receive (RX) pairs between Line
Extenders must be wired in a cross-over fashion such that the TX terminals of Line Extender #1 are
connected to the RX terminals of Line Extender #2 and vice-versa. Each data cable connection point is
labeled next to the terminal block P19 as shown below.

Figure 14. Data Line Terminals