Table 34 outlines the function settings for DIP switch S3:

Table 34. Function Settings for DIP Switch S3

Function Setting

Jitter

Attenuator

Select

S3-1: ON; Place jitter attenuator on RCV side

S3-1: OFF; Place jitter attenuator on XMT side (default setting)

Remote

Management

S3-2: ON; Remote management enabled (only at the REMOTE end)

S3-2: OFF; Remote management disabled (only at the LOCAL end) (default setting)

Loopback

Selection

S3-3: ON; S3-4: ON; None (default setting)
S3-3: OFF; S3-4: ON; Local loopback
S3-3: ON; S3-4: OFF; Analog loopback
S3-3: OFF; S3-4: OFF; Remote loopback

Monitor/Boost

Mode

S3-5: ON; S3-6: ON; Normal operation (No boost) (default setting)
S3-5: OFF; S3-6 ON; 20 dB
S3-5: ON; S3-6 OFF; 26 dB
S3-5: OFF; S3-6 OFF; 32 dB

NRZ Selection

S3-7: ON; Disable NRZ (Required for Passive Mode) (default setting)
S3-7: OFF; Enable NRZ (Line Terminating Mode)

Fiber Type

S3-8: Factory configured; DO NOT CHANGE
S3-9: Factory configured; DO NOT CHANGE
S3-10: Factory configured; DO NOT CHANGE