These switches are factory set according to Table 32 below. It is recommended that the default
configuration (passive mode) is used for most typical applications. Passive mode allows the fiber segment
to pass data unchanged between the T1/E1 segments independent of the actual line coding (AMI, B8ZS, or
HDB3). All errors and fault conditions from one T1/E1 end will pass through the fiber to the other end as
if there were one long T1/E1 connection. Use these settings to insure proper operation of the Model
LE200-RM Line Extender.

Table 32. Factory Settings for the Fiber Optic Transceiver

Function Factory

Setting

T1/E1 mode

T1

Receive Equalizer Gain Limit (EGL)

−30 dB (Limited Long Haul)

Line encoding

AMI (passive mode)

Transmit LIU wave shape (Build-out)

DSX-1 (0 to 133 feet) 0 dB CSU

Receive LIU termination

Receive side 100 ohms enabled

Transmit data source

Standard data

Jitter attenuator

Place jitter attenuator on TX side

Select remote management

Remote management disabled

Loopback selection

No loopback

Monitor/boost mode

No boost

NRZ selection

Disable NRZ (passive mode)