ELECTRICAL SPECIFICATIONS

Power Requirement: 110v, 60 HZ, AC, or International 230v, 50/60HZ, AC

20 amp line required for models with pump

Circuit Protection:

3 AMP Circuit Breaker, 3 AMP Fuse

NOTE: Older buildings, overloaded lines, and bad grounds can affect the

operation of your IcreaseAIR. A regulated dedicated line is recommended.

Operating the machine through a power strip is not recommended.

OPERATING SPEEDS

MODE

8.5 X 11 Sheet(est)

Perf Mode

12,000

Crease Mode

5500

SPECIFICATIONS

Net Weight:

icreaseAIR…………………………………………………..350 lbs

Overall Dimensions: …………………………………………………………………..32”Lx27”Wx26”D

Boxed Dimensions: …………………………………………………………………48”Lx48”Wx52”H

Min. Sheet Size:

………………………………………………………………..5”x5”

Max. Sheet Size:

…………………………………………………………………18”x20”

NOTE: The icreaseAIR is capable of handling many types of applications above and

beyond the standard specifications. It is possible to feed quite a variety of jobs, from

30” sheets to die cut stocks. However, the performance of the icreaseAIR on these

special applications is directly related to the experience of the operator.