Important, Installation – Montigo H38DF User Manual

Page 15

Advertising
background image

Page 15

XG0147 - 150204.1

H*38DF Gas Fireplace

Installation

Figure 14. Corner installation. (NG Models Only)

Figure 14a. Flex installation. (NG Models Only)

45° Corner Installation.
Attach an PEL-45 (45° elbow) directly onto the flue collar. Cut the

PXT-20 to suit, and attach it to the PEL-45. Slide the fireplace into

position and attach to the termination.

45° or less Corner Installation.
Use an PTO-4 termination and an PFL-1 or PFL-2/PFL-2 (12" or 24"

compressed length) and a frame, if appropriate. Flex may be turned

to obtain desired degree of angle required but must not exceed 45°.

Note: Through the wall venting kits are also available for both

the Straight and the Corner Installation. The Kit includes a heat

shield, a PFL-12 (f/f) flexible pipe, and a termination with or without

a mounting frame.

PEL-45 Elbow

PEL-90 Elbow

PXT-18

Heat Shield

Heat Shield

Corner installation is available for H38DF NG models only. Ensure minimum

vertical venting height of 42” is maintained in corner installation.

IMPORTANT

Advertising