Installation

Installing the remote On/Off Wall Switch

The H*38DF* gas valve may be connected to a wall switch. Do NOT

connect any external power to the remote switch. The valve will

generate its own power on a millivolt circuit or will draw its power from

an AC Connection inside the fireplace, depending on the model of the

unit. Use only low voltage wire, and DO NOT connect any external

power to the remote switch.
Refer to Figure 19, 20, or 21 for wiring requirements.
NOTE: The switch location must not exceed 30' from the fireplace.

WARNING:

An inspection of the explosion relief flappers and door

MUST be made prior to lighting the fireplace. Faulty seal

on the door gasket and/or explosion ports will result in

products of combustion leaking into the living space and

may result in carbon monoxide poisoning.