Maintenance, Lighting instructions, General – Montigo H38DF User Manual

Page 34: Cleaning, Hi-lo burner adjustment: (sit nova 820), Hi-lo burner adjustment: (sit proflame 2), Pilot burner adjustment, Caution

Advertising
background image

Page 34

H*38DF Gas Fireplace

XG0147 - 150204.1

Maintenance

Maintenance
Lighting Instructions

See pages 27 to 29.

CAUTION!

„

Fireplace gas control must be in the “OFF” position and pilot

and main burners extinguished when cleaning appliance with

a vacuum.

„

Doors can get very hot. Handle only when cool.

Cleaning

When the fireplace is first activated, there may be some smoking and

a visible film may be left on the glass. This is a normal condition, and is

the result of burning of protective coatings on new metal.

„

Glass must be cleaned periodically to remove any film (which

is a normal by-product of combustion) which may be visible.

Film can easily be removed by removing the door, as shown on

Page 22. Handle the door carefully, and clean it with nonabrasive

glass cleaners. One of the most effective products is Kel Kem.

„

Silicone seals on inner door during initial firing will "off gas",

leaving a visual deposit of a white substance on combustion

chamber walls. This can easily be removed from the chamber

walls using normal household products.

„

Use a vacuum cleaner or whisk broom to keep the control

compartment, burner, and firebox free from dust and lint.

„

Logs may be cleaned periodically with a vacuum to remove soot

or other contaminates.

Hi-Lo Burner Adjustment: (SIT Nova 820).
The H*38DF* is equipped with an adjustable burner, allowing you to

raise or lower the flames. To adjust the flames, locate the black knob

marked 'Hi-Lo', in the centre of the gas control valve (See Figure 32).
„

To raise the flame height, turn the black knob (located behind the

lower control compartment) counter-clockwise.

„

To lower the flame height, turn clockwise.

Figure 32. 'Hi-Lo' Adjustment on the SIT Nova 820 gas valve,

Hi-Lo Burner Adjustment: (SIT Proflame 2).
The H*38DFI is equipped with an adjustable burner, allowing you to

raise or lower the flames. To adjust the flames, locate the black knob

marked 'Hi-Lo', in the centre of the gas control valve (See Figure 33).
„

To raise the flame height, turn the black knob (located behind the

lower control compartment) counter-clockwise.

„

To lower the flame height, turn clockwise.

Figure 33. 'Hi-Lo' Adjustment on the SIT Proflame 2 gas valve.

Manifold Pressure

Test Connection

Pilot Adjustment Screw

Hi Lo Adjustment

Inlet Pressure

Test Connection

Pilot Burner Adjustment.
1.
Locate Pilot Adjustment Screw. (See figure 32 or 33.)
2. Adjust pilot screw to provide properly sized flame as shown.
3. After installing or servicing, leak test with a soap solution with main

burner on. Coat pipe and tubing joints, gasket etc. with soap solution.

Bubbles indicate leaks. Tighten any areas where the bubbles appear

until the bubbling stops completely.

Manifold Pressure

Test Connection

Wall Switch

Power

Generator

Pilot Adjustment Screw

Inlet Pressure

'Hi-Lo' Adjustment Knob

Gas Control Knob (Shown in “Pilot” position)

„

For Natural Gas this appliance requires a minimum inlet pressure

of 5.5" W.C. and a manifold pressure of 3.5" W.C.

„

For Propane Gas this appliance requires a minimum inlet

pressure of 11" W.C. and a manifold pressure of 10" W.C.

„

Always keep the fireplace area clear and free of combustible

materials, as well as gasoline and other flammable vapours

and liquids.

„

Do not use this appliance if any part has been under water.

Immediately call a qualified service technician to inspect the

appliance and to replace any part of the control system and any

gas control which has been under water.

General

„

Have the fireplace and installation inspected yearly. The inspection

must include, but is not limited to, the following:

A visual check of the entire vent system and termination.

An inspection of the explosion relief flappers and the door

gaskets to ensure a proper seal.

An inspection of the burner, vent run, and primary air openings.
An inspection of the gas valve, gas components, and pilot flame.

For your convenience a 1/8" manifold pressure tap is supplied

on the gas valve for a test gauge connection.

Ensure proper log placement as per this manual.
Inspection of all optional equipment; fans, thermostats, etc.
• Inspection of all glass doors and screen for damage and proper