L38DF-ST* Indoor Gas Fireplace

Page 13

XG0810 - 150204.2

Installation

The Venting Graph: L38DF-ST*

Measure the vertical height from the fireplace hearth to the centre of the

termination and the horizontal run from the fireplace flue collar to the wall

flange of the termination. Plot on the Venting Graph Figure 12 with an 'X'.
If the 'X' falls on or above the top boundary of the shaded area, the

installation is acceptable.
Example A: (Acceptable Installation)

If the vertical dimension from the hearth is 96" and the horizontal

run to the wall flange of the vent termination is 72", this would be

an acceptable installation.

Example B: (Acceptable Installation)

If the vertical dimension from the hearth is 60" and the horizontal

run to the wall flange of the vent termination is 144", this would be

an acceptable installation.

Example C: (Unacceptable Installation)

If the vertical dimension from the floor of the fireplace is 48" and

the horizontal run to the wall flange of the vent termination is 108",

this would NOT be an acceptable installation.

Section 3-3-1: Venting Layout: Wall mounted termi-

nation

Selection of components and details of venting layout should

adhere to the following guidelines:

„

Vent terminations must not be recessed in walls or siding.

„

For Heat Shield requirements see Section 3-3-3.

„

Once the proposed venting layout has been determined refer to

Figure 12 or 13 to ensure the layout is acceptable.

Notes Wall Mounted Terminations: TOP VENT

„

All measurements for vertical or horizontal runs are measured

from center of the vent pipe.

„

Venting runs must fall within the limits set by the venting graph,

see Figure 12.

Wall mounted Terminations

The following details are some possible configurations for Wall

mounted terminations.

Figure 12. L38DF-ST* Top Vent Venting Graph for wall mounted

terminations.

Figure 12a. Top Vented, wall mounted installation with 1 elbow. The

vent run must comply with Venting Graph for Top vent, wall

mounted terminations, Figure 11.

Figure 12b. Top Vented, wall mounted Multi-elbow installation. See

Venting Graph for Top vent, wall mounted terminations,

Figure 12.

C

B

36”

42”

A

If your installation does not fall within

the venting parameters, contact a

local Montigo dealer for Power

Venting options.

Unacceptable vent run

within shaded area.

Acceptable vent run

within non-shaded area.

Heat Shield

36” max.

42

Min.

Solid Section

Flex Section

Hearth

150” Max.

Heat

Shield

Termination

Exterior

Wall