Section 3: venting, Installation – Montigo L38DF-ST User Manual

Page 9

Advertising
background image

L38DF-ST* Indoor Gas Fireplace

Page 9

XG0810 - 150204.2

Installation

Section 3: Venting

Figure 8. Flue cover and collar removal, Top Vented fireplace.

Figure 8a. Flue cover and collar installation, Side Vented fireplace.

Section 3-1:

Converting from Top to Side Vent

Use the following instructions to convert an L38DF-ST* for Rear Vent use:

1. Remove the Side flue cover and gasket (5" and 8") on the flue

outlet, as shown in Figure 8.

2. Next, Remove the Top flue collar's (5" and 8") on the flue outlet,

as shown in Figure 8.

3. Install the (removed) Side flue cover and gasket material, to the

Top vent outlet. Fasten the cover with included hardware, as

illustrated Figure 8a.

4. Install the (5" and 8") collars to the Side vent outlet using the

included hardware, as illustrated Figure 8a.

Flue Collar

8” Outer

Flue Collar

5” Inner Flue

Cover Plate

Outer Flue

5” Inner Flue

Cover Plate

8” Outer Flue

Cover Plate

8” Outer

Flue Collar

5” Inner

Flue Collar

Montigo supplies a variety of direct venting and termination options.

The direct vent termination location MUST be selected such that

it is the highest point in the venting assembly. It should also be

selected such that it provides the shortest vent run possible. Should

it be impossible to ensure that the termination is the highest point or

should it be impossible to meet the venting guidelines laid out below

please contact your Montigo dealer to discuss power venting options.

NOTES FOR PLANNING VENTING:

„

Venting can originate from the unit through the top or

through the side.

„

Venting can terminate through the roof or through an
exterior wall
.

„

Refer to Appendix A - Termination Locations to ensure

the planned termination location is acceptable.

„

Once the termination location has been established, refer

to the appropriate section below for installation details

„

All fireplaces shipped from the factory are Top vent.

„

Silicone application is NOT required when joining Mon-

tigo vent pipes and components.

Cover Plate

Note: Images are shown without screens for clarity purposes. How-

ever, your fireplace should not be operated without proper installation

of screens.

Advertising
This manual is related to the following products: