Section 5: Installing the Gas Line

Section 5-1: FUEL CONVERSION

„

Verify that your fireplace is compatible with your available gas

type. (Natural Gas or Propane shown by "N" or "L" in your

model number

„

If gas type is not compatible, contact your local Montigo

representative.

„

Conversion kits must be installed by a qualified service techni-

cian.

Section 5-2: GAS PRESSURE

„

Optimum appliance performance requires proper input pres-

sures.

„

Gas line sizing requirements will be determined in ANSI

Z221.3 National Fuel Gas Code in the USA and CAN/CGA

B149 in Canada.

„

Pressure requirements are:

Gas Pressure

Natural Gas

Propane

Minimum inlet pressure

5.5in. w.c.

11in. w.c.

Manifold pressure

3.5in. w.c.

10in. w.c.

Note: After gas line is connected, each appliance connection,

valve and valve train must be checked while under normal

operating pressure with either a liquid solution, or leak

detection device, to locate any source of leak. Tighten any

areas where bubbling appears or leak is detected until

bubbling stops completely or leak is no longer detected.

DO NOT use a flame of any kind to test for leaks.

„

The manifold outlet pressure is set from the factory to the

appropriate pressure but should be verified.

„

To check pressures, control valves have a provision to re-

move a 1/8” N.PT. plug to be fitted with a hose barb.

„

Montigo requires a service shut off valve be located in an ac-

cessible location to isolate the gas supply.

„

Only install gas shut-off valves approved for use by the state,

province, or other governing body in which the fireplace is

being installed.

Section 5-3: GAS CONNECTION

„

See Figure 19 for location of gas line access.

„

Flexible gas connectors must not exceed 3 feet in length, un-

less allowable within local regulations.

„

Connect incoming gas line to the 1/2"or 3/8" gas inlet port.

„

Purge all air out of gas line.

„

Check appliance connection, valve and valve train under

normal operating pressure with a commercially available leak

check solution.

„

DO NOT USE A FLAME OF ANY KIND TO TEST FOR

LEAKS.

Figure 19. Gas line access.

When pressure testing the fireplace, Gas line, and input system follow the appropriate

local codes or your area. DO NOT connect the fireplace to pressures in excess of

1/2lb. This will damage the gas control valve.

NOTICE

7”

1 3/4”

2 3/8”

1 3/4”

An inspection of the explosion relief flappers and door MUST be made prior to

lighting the fireplace. A faulty seal on the door gasket and/or explosion ports will

result in products of combustion leaking into the living space and may result in

carbon monoxide poisoning.

WARNING

WARNING

When installing the fireplace - gas lines, fittings,

accessories or any other objects cannot impede the

proper movement of the door buckles.