General

„

Have the fireplace and installation inspected yearly. The

inspection must include, but is not limited to, the following:

A visual check of the entire vent system and termination.
An inspection of the explosion relief flappers and the door

gaskets to ensure a proper seal.

An inspection of the burner, vent run, and primary air open-

ings.

An inspection of the gas valve, gas components, and pilot

flame. For your convenience a 1/8" manifold pressure tap is

supplied on the gas valve for a test gauge connection.

Inspection of all optional equipment; fans, thermostats, etc.

„

For Natural Gas this appliance requires a minimum inlet pressure

of 5.5" W.C. and a manifold pressure of 3.5" W.C.

„

For Propane Gas this appliance requires a minimum inlet pres-

sure of 11" W.C. and a manifold pressure of 10" W.C.

„

Always keep the fireplace area clear and free of combustible

materials, as well as gasoline and other flammable vapors and

liquids.

„

Do not use this appliance if any part has been under water. Imme-

diately call a qualified service technician to inspect the appliance

and to replace any part of the control system and any gas control

which has been under water.

„

Inspection of glass doors and screens for damage and proper

installation.

Cleaning

When the fireplace is first activated, there may be some smoking and

a visible film may be left on the glass. This is a normal condition, and

is the result of burning of protective coatings on new metal.

„

Glass must be cleaned periodically to remove any film (which is

a normal by-product of combustion) which may be visible. Film

can easily be removed by removing the door, as shown on Page

21. Handle the door carefully, and clean it with non-abrasive glass

cleaners. One of the most effective products is Kel Kem.

„

Silicone seals on inner door during initial firing will "off gas", leav-

ing a visual deposit of a white substance on combustion chamber

walls. This can easily be removed from the chamber walls using

normal household products.

„

Use a vacuum cleaner or whisk broom to keep the control com-

partment, burner, and firebox free from dust and lint.

„

Clean the primary air openings from lint, embers, dust, etc.

Hi-Lo Burner Adjustment: (SIT Nova 820).

The L38DF-ST* is equipped with an adjustable burner, allowing you

to raise or lower the flames. To adjust the flames, locate the black

knob marked 'Hi-Lo', in the centre of the gas control valve (See

Figure 24).
„

To raise the flame height, turn the black knob (located behind

the lower control compartment) counter-clockwise.

„

To lower the flame height, turn clockwise.

Figure 24.

'Hi-Lo' Adjustment on the SIT Nova 820 gas valve,

Hi-Lo Burner Adjustment: (SIT Proflame 2).

The L38DF-ST* is equipped with an adjustable burner, allowing you

to raise or lower the flames. To adjust the flames, locate the black

knob marked 'Hi-Lo', in the centre of the gas control valve (See

Figure 25).
„

To raise the flame height, turn the black knob (located behind

the lower control compartment) counter-clockwise.

To lower the flame height, turn clockwise.

Figure 25.

'Hi-Lo' Adjustment on the SIT Proflame 2 gas valve.

Manifold Pressure

Test Connection

Pilot Adjustment Screw

Hi Lo Adjustment

Inlet Pressure

Test Connection

Pilot Burner Adjustment.

1. Locate Pilot Adjustment Screw. (See figure 24 or 25.)
2. Adjust pilot screw to provide properly sized flame as shown.
3. After installing or servicing, leak test with a soap solution with

main burner on. Coat pipe and tubing joints, gasket etc. with

soap solution. Bubbles indicate

leaks. Tighten any areas where the

bubbles appear until the bubbling

stops completely.

Manifold Pressure

Test Connection

Wall Switch

Power

Generator

Pilot Adjustment Screw

Inlet Pressure

'Hi-Lo' Adjustment Knob

Gas Control Knob (Shown in “Pilot” position)

Maintenance