Section 6: finishing, Caution, Warning – Montigo L38DF-ST User Manual

Page 21: Installation

Advertising
background image

L38DF-ST* Indoor Gas Fireplace

Page 21

XG0810 - 150204.2

Installation

WARNING

Do not place any materials or objects on top of the

valve blind. Doing so could result in failure of door

relief system or heat dissipation.

Section 6: Finishing

Figure 20. Combustible mantels and facings.

Finishing Around the Fireplace

Combustible mantels and mouldings may be safely installed over the

top and on the front of the fireplace provided that they do not project

beyond shaded area shown in Figure 20.

Fireplace Facing

When sizing the finish material for your fireplace, it is important to remem-

ber the following: THE OPENING MUST NOT BE OBSTRUCTED IN ANY

WAY - to do so restricts the air supply for the control compartments

and heat exchanger it also prevents access for servicing controls.
The face of the fireplace may be painted to match the room decor,

provided you use a heat-resistant paint. Decorative facing must not

extend past the fireplace opening at all, because it will interfere with

the access to retainers for removal of glass door.

Figure 21. Combustible surrounds. Typical both sides.

Mantels & Surrounds

NOTE: National Canadian Gas Association mantel test requirements

are for fire hazard prevention to combustible materials.
New technology, to meet consumer and government demands for the

wise use of energy, has prompted us to manufacture many models of

fireplaces which are hot, fuel and energy efficient.
Please be aware; temperatures over the mantel will rise above normal

room temperature and walls above fireplace may be hot to touch.

Side wall clearances are 3". Combustible surrounds may be installed

with 3" clearance to the side of the fireplace as shown in Figure 21.

We recommend careful consideration be given to the effects of elevated mantel

temperatures which may be in excess of product design, for example: candles, plastic

or pictures. This can cause melting, deformation, discoloration or premature failure of

T.V. radio, and other electronic components.

CAUTION

Horizontal Run (in.)

Vertical Height (in.)

top of fireplace

Steel Stud construction allowable

within the grey area

Metal header

Non-combustible Facing

First combustible stud

Combustible Faceing

Combustible construction

allowed in shaded area

6”

3

Drywall/

Sheetrock

MetalHeader

NonCombustible

Facing Material

6”